Support up to 4 gas runs or 2 liquid runs per module (Flow-X/M, Flow-X/C)
Inputs
6x analog transmitter input, high accuracy Input types are 4 to 20 mA, 0 to 20 mA, 0 to 5 V, 1 to 5 V Accuracy mA inputs; 0.002% FS at 21 °C, 0.008% at full ambient range of 0-60 °C, long-term stability 0.01% per year Resolution: 24 bits. Analog inputs have the same earthing relative to all other electronic devices.
16x digital status inputs. Resolution 100ns (10MHz)
Outputs
4x analog output for process outputs and flow / pressure control. Resolution 14 bits, 0.075% FS. Analog outputs share same ground floating in relation to all other electronics.
16x digital output, open collector. Rating 100mA @24V
El ordenador de caudal Flow-X ofrece conversión de volumen, masa y energía de gases y líquidos, registro de eventos, registro de parámetros e informes utilizando la tecnología más avanzada. Se combinan módulos idénticos en diferentes carcasas, lo que permite ofrecer una versión multicanal, el Flow-X/P, para 1 a 4 canales de medición con pantalla táctil local, o la versión Flow-X/S para instalaciones rentables. El Flow-X cumple los requisitos incluso de las aplicaciones más exigentes y es el compañero ideal para las mediciones de transferencia de custodia.
Medición de gases y líquidos para transferencia de custodia, fines fiscales y de asignación
En tierra y en alta mar: gas natural, GNL, gas de quema, fluidos de proceso, CO₂, H₂
Carga y descarga
Propiedades del equipo:
Configuraciones para series de contadores que cumplen con las normas internacionales, incluidas MID, OIML y AGA
Módulos potentes para aplicaciones exigentes
Cada módulo cuenta con CPU, memoria y el mismo número de entradas y salidas
Interfaz de usuario intuitiva para visualización gráfica y navegador web
Acceso remoto real a través de Ethernet
Ordenador de estación para hasta 8 series de contadores
Ventajas
Planificación e instalación sencillas gracias a la configuración estándar
Conversión de volumen muy precisa gracias a varios ciclos de cálculo por segundo
Gran fiabilidad gracias a los módulos independientes entre sí con conversión de volumen propia, almacenamiento de los valores medidos, estados de los contadores y eventos
Ampliación sencilla de instalaciones gracias a módulos con entradas y salidas uniformes completamente configurables por software
Costes de servicio técnico y mantenimiento reducidos gracias al mantenimiento remoto a prueba de manipulaciones
Integración de sistemas de varios intervalos de medición económica y flexible
La instalación y la monitorización de equipos en una planta de amoníaco presentan desafíos importantes. Engie Energía utiliza soluciones tecnológicas avanzadas, como equipos de comunicación remota en áreas peligrosas.
Schluchseewerk AG quería registrar y optimizar la eficiencia de sus turbinas en la planta de almacenamiento por bombeo de Wehr. Endress+Hauser le ofreció la solución ideal con su caudalímetro "clamp-on" por ultrasonidos.
Digital communications now provide a wealth of additional diagnostic and other information, enabling operational insights unachievable with simple 4-20mA measurements alone.
gas volume conversion, event logging, parameter logging, and reports
Number of applications
Support up to 4 gas runs or 2 liquid runs per module (Flow-X/M, Flow-X/C)
Calculations
Gas property calculations: AGA 5, AGA 8 Part 1, AGA 8 Part 2 (GERG-2008), AGA 10 AGA NX-19 GERG-2008 GERG91mod (GOST 30319.2-1996) GOST 30319.2-2015 GSSSD MR-113 ISO 6976, ISO 12213 Parts 2 and 3 S-GERG Flow rate calculations: AGA 3, AGA 7, AGA 9, AGA 11
Electrical connection
Voltage 24 V DC (± 10%), with redundant connections Current consumption: Flow-X/P0, X/M, X/S: ≤ 0.4 A nominal; ≤ 0.8 A maximal Flow-X/C: ≤ 0.6 A nominal; ≤ 1.0 A maximal
Ambient temperature range
Flow-X/S: -40 °C ... +75 °C Flow-X/C, Flow-X/P, Flow-X/R: 0 °C ... +60 °C
System
CPU and memory: 800 MHz, 512 MB RAM, 1 GB flash memory Clock: Real-time clock, accuracy better than 1 sec/day Gold cap for date and time retention Watchdog: Hardware and software watchdog timer Tamper switch: Mechanical tamper switch to prevent changing of the application and vital parameters within that application
Supported gas chromatographs
Supports all common gas chromatographs (including ABB NGC8200 series, ABB BTU8100, Danalyser, Yamatake HGC, Encal 3000, Angus GQA, Siemens Maxum and Sitrans)
Conformities
2014/32/EU Measuring Instruments Directive (MID)
Directive 2014/30 / EC relating to electromagnetic compatibility
2012/19/EU WEEE Directive (WEEE 2)
2011/65/EU RoHS
OIML R117-1
WELMEC 7.2, 8.3, 8.8
API 21.1
Hazardous area approvals
Applies for FlowX/M and X/S only Class I, Division 2, Groups A, B, C, and D, T4 Class I, Zone 2, Group IIC, T4 IECEx Ex ec IIC Gc ATEX II 3 G Ex ec IIC Gc
Inputs
6x analog transmitter input, high accuracy Input types are 4 to 20 mA, 0 to 20 mA, 0 to 5 V, 1 to 5 V Accuracy mA inputs; 0.002% FS at 21 °C, 0.008% at full ambient range of 0-60 °C, long-term stability 0.01% per year Resolution: 24 bits. Analog inputs have the same earthing relative to all other electronic devices.
16x digital status inputs. Resolution 100ns (10MHz)
Outputs
4x analog output for process outputs and flow / pressure control. Resolution 14 bits, 0.075% FS. Analog outputs share same ground floating in relation to all other electronics.
16x digital output, open collector. Rating 100mA @24V
Continúe seleccionando entre todas las opciones posibles
Valoramos su privacidad
Utilizamos cookies para mejorar su experiencia de navegación, recopilar estadísticas para optimizar la funcionalidad del sitio y ofrecer publicidad o contenido personalizado.
Al seleccionar «Aceptar todas», autoriza nuestro uso de cookies.
Para obtener más detalles, consulta nuestra política sobre cookies .