Differential pressure, capacitive.
Transmitter.
Application: pressure, level, flow.
Membrane: ceramic.
Secondary process barrier.
:: High long term stability.
:: High reliability through process
monitoring.
:: High resistance to abrasion.
:: Enhanced mechanical integrity.
:: Modular.
Predecessor
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-
-
Measuring principle
Differential pressure
-
Characteristic
Digital transmitter with ceramic measuring diapragms
Modular transmitter
Long-term stability
Enhanced safety via self diagnostic functions
Secondary process barrier -
Supply voltage
4...20mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC -
Reference Accuracy
0,075%
"PLATINUM" 0,05% -
Long term stability
0,05% of URL/year
0,125% of URL/5 years -
Process temperature
-20°C...85°C
(-4°F...185°F) -
Ambient temperature
-20°C...85°C
(-4°F...185°F) -
Measuring cell
25mbar...3bar
(10inH2O...45psi) -
Max. overpressure limit
on one side:
100 bar
(1500 psi) -
Process connection
1/4-18NPT
RC1/4" -
Communication
4...20mA HART
PROFIBUS PA
FOUNDATION Fieldbus -
Certificates / Approvals
ATEX
FM
CSA
NEPSI
IECEx -
Safety approvals
SIL
Overfill prevention WHG -
Design approvals
EN10204-3.1
-
Marine approvals
GL
-
Specialities
diagnostic functions
-
Successor
PMD75
-
Measuring principle
Differential pressure
-
Characteristic / Application
Digital transmitter with ceramic measuring diaphragms
Modular transmitter
Long term stability
Enhanced safety via self diagnostic functions
Secondary process barrier -
Supply / Communication
4...20 mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC -
Accuracy
0,075%
"PLATINUM" 0,05% -
Long term stability
0,05% of URL/year
-
Ambient temperature
-20°C...85°C
(-4°F...185°F) -
Process temperature
-20°C...85°C
(-4°F...185°F) -
Process pressure / max. overpressure limit
150 bar (2250psi)
-
Pressure measuring range
25mbar...3 bar
(0.36psi...45psi) -
Main wetted parts
Ceramic
Alloy C276
316L
Monel
Tantalum -
Process connection
1/4-18NPT
RC1/4" -
Max. measurement distance
30m (98ft)H2O
-
Communication
4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus -
Certificates / Approvals
ATEX
FM
CSA
NEPSI
IECEx
SIL
GL marine
WHG/ Overfill prevention
EN10204-3.1 -
Options
HistoROM/M-Dat
4-line digital display
SS- or Aluminiumhousing
Separate housing -
Successor
PMD75
-
Application limits
Measuring cell:
Ceramic
-
Measuring principle
Differential pressure
-
Product headline
Digital transmitter with ceramic measuring diaphragms
Modular transmitter
Long-term stability
Enhanced safety via self diagnostic functions
Secondary process barrier -
Max. measurement error
0,075%
"PLATINUM" 0,05% -
Max. process pressure
max. 150bar
(max. 2.175 psi) -
Medium temperature range
Temperature gradient from pressure piping
-
Display/Operation
Option
-
Outputs
4...20mA HART
PROFIBUS PA
FOUNDATION Fieldbus -
Digital communication
HART
PROFIBUS PA
FOUNDATION Fieldbus -
Hazardous area approvals
ATEX
FM
CSA
NEPSI
IECEx
SIL
Schiffbau GL
WHG/ Überfüllsicherung
EN 10204-3.1
-
Measuring principle
Differential pressure
-
Product headline
Digital transmitter with ceramic measuring diaphragms
Modular transmitter
Long-term stability
Enhanced safety via self diagnostic functions
Secondary process barrier -
Max. measurement error
0,075%
"PLATINUM" 0,05% -
Max. process pressure
max. 150bar
(max. 2.172 psi) -
Medium temperature range
Temperature gradient from pressure piping
-
Display/Operation
Option
-
Outputs
4...20mA HART
PROFIBUS PA
FOUNDATION Fieldbus -
Digital communication
HART
PROFIBUS PA
FOUNDATION Fieldbus -
Hazardous area approvals
ATEX
FM
CSA
NEPSI
IECEx
SIL
Schiffbau GL
WHG/ Überfüllsicherung
EN 10204-3.1
-
Measuring principle
Differential pressure
-
Product headline
Digital transmitter with ceramic measuring diaphragms
Modular transmitter
Long-term stability
Enhanced safety via self diagnostic functions
Secondary process barrier -
Max. measurement error
0,075%
"PLATINUM" 0,05% -
Max. process pressure
max. 150bar
(max. 2.172 psi) -
Medium temperature range
Temperature gradient from pressure piping
-
Display/Operation
Option
-
Outputs
4...20mA HART
PROFIBUS PA
FOUNDATION Fieldbus -
Digital communication
HART
PROFIBUS PA
FOUNDATION Fieldbus -
Hazardous area approvals
ATEX
FM
CSA
NEPSI
IECEx
SIL
Schiffbau GL
WHG/ Überfüllsicherung
EN 10204-3.1
-
-
Operating Instruction (BA)
Deltabar S FMD77, FMD78, PMD75 HART V02.30.zz Operating Instructions
-
Operating Instruction (BA)
English version - 07/2024New version available in EnglishDifferential pressure transmitter with metal sensors
EN 11/07/202401/03/2018Language:
English
Version:
11/07/2024
File size:
1.1 MB
File name:
BA00270PEN_2122.pdf
-
-
-
Operating Instruction (BA)
Cerabar S /Deltabar S /Deltapilot S Description of Instrument Function HART
-
Operating Instruction (BA)
English version - 10/2011New version available in EnglishCerabar S PMC71, PMP71, PMP75 Pressure transmitter
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75 Differential pressure
transmitter
Deltapilot S FMB70 Hydrostatic pressure transmitterEN 01/10/2011Language:
English
Version:
01/10/2011
File size:
6.3 MB
File name:
BA00274PEN_1311.pdf
-
-
-
Short Instruction (KA)
Deltabar S FMD77, FMD78, PMD75
-
Short Instruction (KA)
English version - 06/2022New version available in EnglishDifferential pressure measurement
EN 30/06/202201/10/2011Language:
English
Version:
30/06/2022
File size:
1.4 MB
File name:
KA01024PEN_1921-00.pdf
-
-
-
Short Instruction (KA)
Cerabar S, Deltabar S, Deltapilot S - Exchange of HistoROM module
-
Short Instruction (KA)
English version - 04/2021New version available in EnglishCerabar S, Deltabar S, Deltapilot S - Exchange of HistoROM module
EN 20/04/2021Language:
English
Version:
20/04/2021
File size:
435.4 KB
File name:
KA00599P_A2.pdf
-
-
-
Short Instruction (KA)
Conversion instructions Cerabar S PMC/PMP7x and Deltabar S PMD/FMD7x from software version 1.x to software Version 2.x or higher
-
Short Instruction (KA)
English version - 05/2021New version available in EnglishConversion instructions Cerabar S PMC/PMP7x and Deltabar S
PMD/FMD7x from software version 1.x to software Version 2.x or higherEN 19/05/2021Language:
English
Version:
19/05/2021
File size:
2.3 MB
File name:
KA00615PA2_0108.pdf
-
-
-
Short Instruction (KA)
Cerabar S, Deltabar S, Deltapilot S - Exchange of the push buttons
-
Short Instruction (KA)
English version - 05/2021New version available in EnglishCerabar S, Deltabar S, Deltapilot S - Exchange of the push buttons
EN 17/05/2021Language:
English
Version:
17/05/2021
File size:
396.6 KB
File name:
KA00610PA2_0312.pdf
-
-
-
Short Instruction (KA)
Deltabar S FMD77, FMD78, PMD75
-
Short Instruction (KA)
English version - 06/2022New version available in EnglishDifferential pressure measurement
EN 30/06/2022Language:
English
Version:
30/06/2022
File size:
1.4 MB
File name:
KA01018PEN_1921-00.pdf
-
-
-
Installation Instructions (EA)
Sensor assembly for PMD70 Installation instruction
-
Installation Instructions (EA)
English version - 04/2012New version available in EnglishDeltabar S
EN 18/04/2012Language:
English
Version:
18/04/2012
File size:
474.7 KB
File name:
EA01007PA2_0112.pdf
-
-
-
Installation Instructions (EA)
Harting plug HAN7D Installation instruction
-
Installation Instructions (EA)
English version - 04/2012New version available in EnglishCerabar M/S, Deltabar M/S, Deltapilot M/S
EN 11/04/2012Language:
English
Version:
11/04/2012
File size:
292.8 KB
File name:
EA0006PA2_0810.pdf
-
-
-
Installation Instructions (EA)
Aluminum housing T14 Installation instruction
-
Installation Instructions (EA)
English version - 05/2012New version available in EnglishCerabar S, Deltabar S, Deltapilot S
EN 16/05/2012Language:
English
Version:
16/05/2012
File size:
460.8 KB
File name:
EA01015PA2_0112.pdf
-