Specs at a glance
-
Measuring principle
TDLAS
-
Measured Variables
Concentration
Cell Pressure
Cell Temperature -
Hazardous area approvals
CSA Class I, Division 2
CSA Class I, Zone 2
Field of application
Using patented tunable diode laser absorption spectroscopy (TDLAS) technology, the SS2100 gas analyzer measures specific gases (H2O, CO2, and H2S) with precision while avoiding interferences that are common with traditional infrared analyzers. The SS2100 analyzer requires little maintenance and does not need recalibration or periodic replacement parts.
Gas analysis: ppb level measurement of H2O, ppm level measurement of H2O, H2S, and CO2, and percent (%) level measurement of H2S and CO2
Natural gas: production, storage, transportation, distribution
Refinery: hydrogen recycle, catalytic reforming, flaring, cracking
Gas processing: fractionation, sour/acid gas removal
LNG: liquefication, custody transfer
Petrochemical: cracking, caustic wash tower
CCUS: measure trace H2S and H2O in 100% CO2
Benefits
Accurate, real-time measurements
Low cost of ownership, no consumables and virtually maintenance-free and reliable in harsh environments
Available to measure up to 3 analytes in one unit (2-packs or 3-packs)
Provides measurements not hampered by wet-up (absorption) or dry-down (desorption)
Dependable with greater repeatability than surface-based sensors
Analog and serial outputs for remote monitoring
Available for following measurements: H2O, CO2, H2S
Xpert selection
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Success stories
-
Measuring principle
TDLAS
-
Product Headline
An advanced gas analyzer for hydrogen sulfide (H2S) measurement. The SS2100 uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.
-
Channels
1
-
Analyte and Measurement ranges
H2S (Hydrogen Sulfide):
0 to 10 ppmv
0 to 1000 ppmv
0 to 5000 ppmv
0 to 5% volume -
Measured Variables
Concentration
Cell Pressure
Cell Temperature -
Ambient Temperature range
-20 to 50°C (-4 to 122°F)
Optional: -10 to 60°C (14 to 140°F) -
Operating Pressure range
Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional) -
Analyzer Wetted materials
316L stainless steel
FKM O-Rings
Glass -
Power supply
120 or 240 VAC ± 10 %, 50 to 60 Hz, 300W
(18 to 24 VDC - optional for electronics only)
3 Amps max at 120 VAC , 1.5 Amps max at 240 VAC -
Communication
Analog Output: Two 4-20mA Isolated, 1200 ohms at 24 VDC max load
Serial: RS232C and Ethernet
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs: 2, Flow Alarm, Validation Request -
Housing materials
Electronics: 304 or 316L stainless steel
Sample System Enclosure: 304 or 316L stainless steel -
Hazardous area approvals
CSA Class I, Division 2
CSA Class I, Zone 2 -
Degree of protection
IP66, Type 4X
-
Measuring principle
TDLAS
-
Product Headline
An advanced gas analyzer for moisture (H2O) measurement. The SS2100 uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.
-
Channels
1
-
Analyte and Measurement ranges
H2O (Moisture):
0 to 10 ppmv
0 to 100 ppmv
0 to 50 ppmv
0 to 5000 ppmv -
Measured Variables
Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature -
Ambient Temperature range
-20 to 50°C (-4 to 122°F)
Optional: -10 to 60°C (14 to 140°F) -
Operating Pressure range
Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional) -
Analyzer Wetted materials
316L stainless steel
FKM O-Rings
Glass -
Power supply
120 or 240 VAC ± 10 %, 50 to 60 Hz, 300W
(18 to 24 VDC - optional for electronics only)
3 Amps max at 120 VAC , 1.5 Amps max at 240 VAC -
Communication
Analog Output: Two 4-20mA Isolated, 1200 ohms at 24 VDC max load
Serial: RS232C and Ethernet
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs: 2, Flow Alarm, Validation Request -
Housing materials
Electronics: 304 or 316L stainless steel
Sample System Enclosure: 304 or 316L stainless steel -
Hazardous area approvals
CSA Class I, Division 2
CSA Class I, Zone 2 -
Degree of protection
IP66, Type 4X
-
Measuring principle
TDLAS
-
Product Headline
An advanced gas analyzer for carbon dioxide (CO2) measurement. The SS2100 uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.
-
Channels
1
-
Analyte and Measurement ranges
CO2 (Carbon Dioxide):
0 to 10 ppmv
0 to 1000 ppmv
0 ppmv to 5000 ppmv
0 to 5% volume
0 to 10% volume
0 to 20% volume -
Measured Variables
Concentration
Cell Pressure
Cell Temperature -
Ambient Temperature range
-20 to 50°C (-4 to 122°F)
Optional: -10 to 60°C (14 to 140°F) -
Operating Pressure range
Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional) -
Analyzer Wetted materials
316L stainless steel
FKM O-Rings
Glass -
Power supply
120 or 240 VAC ± 10 %, 50 to 60 Hz, 300W
(18 to 24 VDC - optional for electronics only)
3 Amps max at 120 VAC , 1.5 Amps max at 240 VAC -
Communication
Analog Output: Two 4-20mA Isolated, 1200 ohms at 24 VDC max load
Serial: RS232C and Ethernet
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs: 2, Flow Alarm, Validation Request -
Housing materials
Electronics: 304 or 316L stainless steel
Sample System Enclosure: 304 or 316L stainless steel -
Hazardous area approvals
CSA Class I, Division 2
CSA Class I, Zone 2 -
Degree of protection
IP66, Type 4X
-
Measuring principle
TDLAS
-
Product Headline
Advanced multi-channel gas analyzer for hydrogen sulfide (H2S) and moisture (H2O), also known as a 2-Pack. The SS2100 uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.
-
Channels
2
-
Analyte and Measurement ranges
H2S (Hydrogen Sulfide):
0 to 10 ppmv (minimum)
0 to 1000 ppmv (maximum)
H2O (Moisture):
0 to 100 ppmv (minimum)
0 to 5000 ppmv (maximum) -
Measured Variables
Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature -
Ambient Temperature range
-20 to 50°C (-4 to 122°F)
Optional: -10 to 60°C (14 to 140°F) -
Operating Pressure range
Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional) -
Analyzer Wetted materials
316L stainless steel
FKM O-Rings
Glass -
Power supply
120 or 240 VAC ± 10 %, 50 to 60 Hz, 300W
(18 to 24 VDC - optional for electronics only)
3 Amps max at 120 VAC , 1.5 Amps max at 240 VAC -
Communication
Analog Output: Four 4-20mA Isolated, 1200 ohms at 24 VDC max load
Serial: RS232C and Ethernet (H2S) and RS232C or Ethernet (H2O)
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs (H2S): 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs (H2S): 2, Flow Alarm, Validation Request
Digital Outputs (H2O): 2, Concentration Alarm, General Fault -
Housing materials
Electronics: 304 or 316L stainless steel
Sample System Enclosure: 304 or 316L stainless steel -
Hazardous area approvals
CSA Class I, Division 2
CSA Class I, Zone 2 -
Degree of protection
IP66, Type 4X
-
Measuring principle
TDLAS
-
Product Headline
Advanced multi-channel gas analyzer for hydrogen sulfide (H2S) and carbon dioxide (CO2), also known as a 2-Pack. The SS2100 uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.
-
Channels
2
-
Analyte and Measurement ranges
H2S (Hydrogen Sulfide):
0 to 10 ppmv (minimum)
0 to 1000 ppmv (maximum)
CO2 (Carbon Dioxide):
0 to 5000 ppmv
0 to 5% volume
0 to 10% volume
0 to 20% volume -
Measured Variables
Concentration
Cell Pressure
Cell Temperature -
Ambient Temperature range
-20 to 50°C (-4 to 122°F)
Optional: -10 to 60°C (14 to 140°F) -
Operating Pressure range
Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional) -
Analyzer Wetted materials
316L stainless steel
FKM O-Rings
Glass -
Power supply
120 or 240 VAC ± 10 %, 50 to 60 Hz, 300W
(18 to 24 VDC - optional for electronics only)
3 Amps max at 120 VAC , 1.5 Amps max at 240 VAC -
Communication
Analog Output: Four 4-20mA Isolated, 1200 ohms at 24 VDC max load
Serial: RS232C and Ethernet (H2S) and RS232C or Ethernet (CO2)
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs (H2S): 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs (H2S): 2, Flow Alarm, Validation Request
Digital Outputs (CO2): 2, Concentration Alarm, General Fault -
Housing materials
Electronics: 304 or 316L stainless steel
Sample System Enclosure: 304 or 316L stainless steel -
Hazardous area approvals
CSA Class I, Division 2
CSA Class I, Zone 2 -
Degree of protection
IP66, Type 4X
-
Measuring principle
TDLAS
-
Product Headline
Advanced multi-channel gas analyzer for hydrogen sulfide (H2S), moisture (H2O), and carbon dioxide (CO2), also known as a 3-Pack. The SS2100 uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.
-
Channels
3
-
Analyte and Measurement ranges
H2S (Hydrogen Sulfide):
0 to 10 ppmv (minimum)
0 to 1000 ppmv (maximum)
H2O (Moisture):
0 to 100 ppmv (minimum)
0 to 5000 ppmv (maximum)
CO2 (Carbon Dioxide):
0 to 5000 ppmv
0 to 5% volume
0 to 10% volume
0 to 20% volume -
Measured Variables
Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature -
Ambient Temperature range
-20 to 50°C (-4 to 122°F)
Optional: -10 to 60°C (14 to 140°F) -
Operating Pressure range
Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional) -
Analyzer Wetted materials
316L stainless steel
FKM O-Rings
Glass -
Power supply
120 or 240 VAC ± 10 %, 50 to 60 Hz, 300W
(18 to 24 VDC - optional for electronics only)
3 Amps max at 120 VAC , 1.5 Amps max at 240 VAC -
Communication
Analog Output: Four 4-20mA Isolated, 1200 ohms at 24 VDC max load
Serial: RS232C and Ethernet (H2S) and RS232C or Ethernet (H2O/CO2)
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs (H2S): 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs (H2S): 2, Flow Alarm, Validation Request
Digital Outputs (H2O/CO2): 2, Concentration Alarm, General Fault -
Housing materials
Electronics: 304 or 316L stainless steel
Sample System Enclosure: 304 or 316L stainless steel -
Hazardous area approvals
CSA Class I, Division 2
CSA Class I, Zone 2 -
Degree of protection
IP66, Type 4X
-
-
Operating Instruction (BA)
SS2100-series TDLAS Gas Analyzer Sample Conditioning System Operating Instructions
-
Operating Instruction (BA)
English version - 02/2024Commissioning, operation, and maintenance details for the
SS2100-series TDLAS Gas Analyzer Sample Conditioning SystemEN 21/02/2024Language:
English
Version:
21/02/2024
File size:
1.3 MB
File name:
BA02337CEN_0123.pdf
-
-
-
Operating Instruction (BA)
SS2100 TDLAS Gas Analyzer Operating Instructions
-
Operating Instruction (BA)
English version - 06/2023Commission, operation, and maintenance details for the
SS2100 TDLAS Gas AnalyzerLanguage:
English
Version:
26/06/2023
File size:
10.3 MB
File name:
BA02281CEN_0123.pdf
-
-
-
Operating Instruction (BA)
TDL measurement cell Operating Instructions
-
Operating Instruction (BA)
English version - 08/2024Operation and maintenance details for TDLAS gas analyzer
measurement cellsEN 02/08/2024Language:
English
Version:
02/08/2024
File size:
1.3 MB
File name:
BA02188CEN_0224.pdf
-
-
-
Device Parameter (GP)
FS 5.16 Description of device parameters
-
Device Parameter (GP)
English version - 10/2024Expert-level description and operational information
for device parametersEN 15/10/202417/09/2021Language:
English
Version:
15/10/2024
File size:
2.5 MB
File name:
GP01177CEN_0224.pdf
-
-
-
Device Parameter (GP)
HC 12 firmware Description of device parameters
-
Device Parameter (GP)
English version - 08/2024Expert-level description and operational information for
device parametersLanguage:
English
Version:
02/08/2024
File size:
2.1 MB
File name:
GP01181CEN_0224.pdf
-
-
-
Device Parameter (GP)
NS 5.14 Firmware Description of device parameters
-
Device Parameter (GP)
English version - 10/2024Expert-level description and operational information for
device parametersEN 15/10/2024Language:
English
Version:
15/10/2024
File size:
2.6 MB
File name:
GP01180CEN_0224.pdf
-
-
-
Installation Instructions (EA)
TDLAS cell assembly mirror cleaning Installation Instructions
-
Installation Instructions (EA)
English version - 07/2024Instructions for cleaning the 0.1 m, 0.8 m, 8 m/28 m
measurement cell mirror for multiple product platformsEN 29/07/2024Language:
English
Version:
29/07/2024
File size:
404.3 KB
File name:
EA01381CEN_0224.pdf
-
-
-
Ex Safety Instruction (XA)
SS2100 2-Pack, 3-Pack TDLAS Gas Analyzer
-
Ex Safety Instruction (XA)
English version - 10/2021Safety Instructions for the SS2100 2-Pack, 3-Pack TDLAS Gas Analyzer
Language:
English
Version:
08/10/2021
File size:
2.9 MB
File name:
XA02751CEN_01.21.pdf
-
-
-
Ex Safety Instruction (XA)
SS2100 TDLAS Gas Analyzer
-
Ex Safety Instruction (XA)
English version - 10/2024Safety Instructions for the SS2100 TDLAS Gas Analyzer
EN 22/10/2024Language:
English
Version:
22/10/2024
File size:
1.4 MB
File name:
XA02750CEN_0324.pdf
-
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .