This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
Predecessor
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-
-
Measuring principle
Electromagnetic
-
Product headline
Wafer flowmeter for the water and wastewater industry.
For basic water applications, optimized for limited space and plastic pipe installations. -
Sensor features
Easy, fast centering of the sensor – innovative housing construction. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Short face-to-face length and low weight. Integrated ground disks made of stainless steel. International drinking water approvals. -
Transmitter features
Safe operation – no need to open the device due to display with touch control, background lighting. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
Transmitter housing made of durable polycarbonate or aluminium. WLAN access. Integrated data logger: measured values monitoring. -
Nominal diameter range
DN 25...100
1"...4" -
Wetted materials
Liner: Polyamide
Electrodes: 1.4435 (316L) -
Measured variables
Volume flow, mass flow
-
Max. measurement error
Volume flow: ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
-
Measuring range
9 to 4700 dm³/min (2.5 to 1250 gal/min)
-
Max. process pressure
PN 16, Class 150, 10K
-
Medium temperature range
0 to +60 °C (+32 to +140 °F)
-
Ambient temperature range
–20 to +60 °C (–4 to +140 °F)
-
Sensor housing material
AlSi10Mg, coated
Sensor connection housing: AlSi10Mg, coated -
Transmitter housing material
Polycarbonat; AlSi10Mg, coated
-
Degree of protection
Compact version: IP66/67, type 4X enclosure
Sensor remote version: IP66/67, type 4X enclosure
Transmitter remote version: IP66/67, Type 4X enclosure -
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display, web browser and operating tools possible -
Outputs
3 ouputs:
0‐20 mA/4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Pulse/frequency output (passive)
Switch output (passive) -
Inputs
Status input
-
Digital communication
HART, PROFIBUS DP, EtherNet/IP, Modbus RS485
-
Power supply
AC 100 to 240 V / AC/DC 24 V
-
Hazardous area approvals
cCSAus
-
Product safety
CE, C-tick, EAC marking
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Pressure approvals and certificates
CRN
-
Hygienic approvals and certificates
ACS, KTW/W270, NSF 61, WRAS BS 6920